Shipping restrictions:
Please note this item only ships within the USA.
We do not ship outside the USA.
Three Output Traffic Controller / Sequencer
Model# MICRO-3 (in Plastic PCB carrier)
Standard Sequence:
GREEN
YELLOW
RED
(repeat)
If you have a 3-light traffic signal hanging in your game room, basement, garage, etc. and would like to make it operate like a REAL stop light, you are in the right place. Measuring only 2-1/8" X 1-7/8" (Plastic Carrier Dimensions), this board fits easily into a standard traffic signal.
Features:
Fully Independent light-times:
Yellow duration is not tied to red/green duration
Red and Green timing does not have to be the same
Extended cycle timing range from 1/2 second to over 20 MINUTES per light
Ultra Compact Size (Approx. 2" X 2")
Screw-Terminal connections, eliminating the need for soldering
100 Watts per output channel
LED compatible (120 vac)
Simple TIME-SETTING procedure
Wiring Diagram is Included (download PDF )
User-replaceable fuse (Type GMA 2 - 2.5A)
All solid-state on-board switching electronics
120 VAC 60HZ standard voltage operation
Retains timing even if power is removed
OVERVIEW
Each lights timing can be set differently, with a possible range of 1/4 second to 20 minutes PER LIGHT. Yellow-Light timing is not tied to the RED / GREEN times.
The fuse is user replaceable. Fuse type is GMA 2A - 2.5A 125/250VAC available from any local Home Depot or Electronic store.
MOUNTING:
The plastic carrier can be adhered to any flat, non-porous surface with double sided sticky tape.
Every unit is fully tested before shipment. A wiring diagram is included with circuit board.
instructions PDF link:
http://www.joezgarage.com/Micro-3-inst.pdf
WARNING: Basic electrical wiring skills for this item are required.
Familiarity with 120 VAC / High Voltages is also required.
Improper wiring of this unit can result in an electrical shock.
Controller / Sequencer Specifications
Range (Min - Max)
Operating Voltage: 108 - 120 VAC
Output Channels:
3 signal: green, yellow, red
Total Wattage per output channel: 100 watts @ 120VAC
Green Light Timing Range: From 1/2 second to 20 MINUTES
Yellow Light Timing Range: From 1/2 second to 20 MINUTES
Red Light Timing Range: From 1/2 second to 20 MINUTES
Setting timing overview...
Using a plastic pen or similar non-conductive item, press and hold down TIME-SET button for 5 seconds until TIME-SET-LED comes on, then release button.
Press and release the TIME-SET button when you want the signal to advance to the next light. Do this for each light.
Once the red-light timing is set, the TIME-SET-LED will turn off and the controller will start normal operation.
note: The new time settings will remain in memory EVEN IF POWER IS REMOVED.