Three Output Traffic Controller / Sequencer
Model# MPS-3
(MPS = Multi-Pattern Sequencer)
Designed to run multiple types of signals.
Like having 5 controllers in one!
Default patterns included:
#1 3-light G-Y-R signal
#2 3-light with 1/2 second OFF GAP between changes
#3 UK-1 (R+Y, G, Y, R [repeat] )
#4 1944 Darley (G, G+Y, Y, Y+R, R, R+Y, Y, Y+G [repeat] )
#5 Flashing RED (1/2 second intervals)
#6 Flashing YELLOW
#7 Alternating RED / YELLOW
#8 PED Walk Don't/Walk (works with separate WALK and DON'T signals as well as WALK, DON'T-WALK signals)
Custom Patterns Available
Approx. Dimensions 2-1/2" X 3"
Input voltage: 120VAC
Features:
User programmable timing
Independent phase times
Multiple Pattern capable
Extended cycle timing range from 1/2 second to over 20 MINUTES per step
Screw-Terminal connections, eliminating the need for soldering
140 Watts per output channel
LED compatible (120 vac)
Simple TIME-SETTING procedure
User-replaceable fuse (Type GMA 2 - 2.5A)
Retains timing even if power is removed
OVERVIEW
There are two push buttons on the circuit board:
Time Set: Used to set the timing for each step in the selected sequence
Sequence Select: Steps through the difference sequences / modes of operation.
Timing for each step can be set differently, with a possible range of 1/4 second to 20 minutes PER STEP.
The fuse is user replaceable. Fuse type is GMA 2A - 2.5A 125/250VAC available from any local Radio Shack or Electronic store.
MOUNTING:
The Circuit board mounts with the four holes located in each corner, and should be mounted away from any metal surface by at least 1/4".
Aluminum stand-offs are recommended for secure mounting. Adhesive tie-wrap blocks can be used
as well.
Every unit is fully tested before shipment. A wiring diagram is included with circuit board.
WARNING: Basic electrical wiring skills for this item are required.
Familiarity with 120 VAC / High Voltages is also required.
Controller / Sequencer Specifications
Range (Min - Max)
Operating Voltage: 108 - 120 VAC
Output Channels: 3 (numbered 1 through 3)
Total Wattage per output channel: 140 watts @ 120VAC
Setting timing overview...
Hold down TIME-SET button for 5 seconds until TIME-SET-LED comes on, then release button.
Tap the TIME-SET button when you want the signal to advance to the next light. Do this for each light.
Once the last step in the sequence is set, the TIME-SET-LED will turn off and the controller will start normal sequence operation.
note: The new time settings will remain in memory EVEN IF POWER IS REMOVED.
Customized sequences available upon request.